• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Liu, Xueyan (Liu, Xueyan.) | Peng, Dong (Peng, Dong.) | Guo, Wei (Guo, Wei.) | Ma, Xibo (Ma, Xibo.) | Yang, Xin (Yang, Xin.) | Tian, Jie (Tian, Jie.)

Indexed by:

EI Scopus

Abstract:

Photoacoustic imaging (PAI) has been employed to reconstruct endogenous optical contrast present in tissues. At the cost of longer calculations, a compressive sensing reconstruction scheme can achieve artifact-free imaging with fewer measurements. In this paper, an effective acceleration framework using the alternating direction method (ADM) was proposed for recovering images from limited-view and noisy observations. Results of the simulation demonstrated that the proposed algorithm could perform favorably in comparison to two recently introduced algorithms in computational efficiency and data fidelity. In particular, it ran considerably faster than these two methods. PAI with ADM can improve convergence speed with fewer ultrasonic transducers, enabling a high-performance and cost-effective PAI system for biomedical applications. © 2012 Xueyan Liu et al.

Keyword:

Photoacoustic effect Ultrasonic transducers Image processing Computational efficiency Compressed sensing Cost effectiveness Medical applications

Author Community:

  • [ 1 ] [Liu, Xueyan]Sino-Dutch Biomedical and Information Engineering School, Northeastern University, Shenyang, Liaoning 110004, China
  • [ 2 ] [Peng, Dong]Life Sciences Research Center, School of Life Sciences and Technology, Xidian University, Xi'an, Shaanxi 710071, China
  • [ 3 ] [Guo, Wei]College of Electronic Information and Control Engineering, Beijing University of Technology, Beijing, Hebei 100124, China
  • [ 4 ] [Ma, Xibo]Intelligent Medical Research Center, Institute of Automation and Chinese Academy of Sciences, Beijing, Hebei 100190, China
  • [ 5 ] [Yang, Xin]Intelligent Medical Research Center, Institute of Automation and Chinese Academy of Sciences, Beijing, Hebei 100190, China
  • [ 6 ] [Tian, Jie]Sino-Dutch Biomedical and Information Engineering School, Northeastern University, Shenyang, Liaoning 110004, China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

International Journal of Biomedical Imaging

ISSN: 1687-4188

Year: 2012

Volume: 2012

ESI Discipline: ENGINEERING;

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count: 30

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 8

Online/Total:565/10598723
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185