Indexed by:
Abstract:
Shear wall with concrete filled round steel tube columns and concealed bracing is presented. This new composite shear wall consists of two kinds of composition. One is composition of two bearing systems, including concrete filled steel tube frame, steel truss and shear wall, the other is composition of two materials, including steel and concrete. So it is a multiple composite shear wall. The experiment was carried out on the seismic behavior of three 1/5 scale mid-rise shear walls. Based on the experimental study, the stiffness and its attenuation, bearing capacity, ductility, hysteretic property, energy dissipation and failure phenomena of each shear wall are contrastively analyzed. The formulas of bearing capacity and stiffness are established. The results obtained from the formulas and those from experiment are in good agreement. The results show that the seismic behavior of shear wall with concrete filled round steel tube columns and concealed bracing is improved evidently compared with traditional reinforced concrete shear wall in high axial-load ratio.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Southeast University (Natural Science Edition)
ISSN: 1001-0505
Year: 2009
Issue: 6
Volume: 39
Page: 1187-1192
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count: 9
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 4
Affiliated Colleges: