Abstract:
A novel electronics cooling technology-electrohydrodynamic (EHD) micropump was fabricated. The EHD micropump was designed with an array of planar comb finger electrodes and driven by DC voltage, The testing result indicates that the pumping performance is proportional to the input voltage and inverse proportion to the channel height, the fluid with high permittivity and low viscosity will increase the pumping performance, and the cleanness degree of device will greatly influence EHD micropump ageing and effect.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Engineering Thermophysics
ISSN: 0253-231X
Year: 2009
Issue: 5
Volume: 30
Page: 857-859
ESI Discipline: PHYSICS;
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 6
Affiliated Colleges: