After the UASB treatment in the trial experiment, the landfill leachate in Liulitun Landfill Yard, with COD and ammonia-nitrogen concentration being 2350-2600 mg/L and about 1300 mg/L respectively, was inefficient in being biochemicalized and low in C/N, which required physico-chemical treatment before advanced biochemical treatment. This experiment introduced Fenton reagent oxidation first and then chemical coagulation, so as to compare removal effects under different dosages. Results showed that the combination of oxidation of Fenton reagent and chemical deposition was effective in the removal of turbidity, COD and ammonia-nitrogen in landfill leachate. Under the condition of cFe2+ = 0.03 mol/L, cH2O2 = 0.09 mol/L, ρPAC = 800 mg/L, ρKP1207B = 10 mg/L, this method was particularly effective, with the removal rates being 62%, 54% and 35% respectively.