The PGC homodyne demodulation technology is used frequently to demodulate sensing signals from interferometric Optical fiber hydrophone. However, it is difficult for the system to achieve the optimum performance because the electronic components which constitute the analog circuit of the PGC homodyne demodulation system have some problems such as overload, improper resistance, etc. For overcoming these disadvantages of the analog circuit mentioned above, a digital PGC homodyne demodulation system based on LabVIEW platform is developed in this paper, it is proved that the digital PGC homodyne demodulation system has good stability and practical feasibility.