In modern era, one of the rising power quality (PQ) concern is harmonics distortion (HD). The HD is usually produced by increase in the utilization of nonlinear user loads at domestic level. It not only spoils the PQ but also have harmful effects on electrical appliances. So, this paper presents a new approach to mitigate the HD in home appliances rapidly by utilizing the active band pass filter (ABPF). The fast Fourier transform (FFT) technique is employed for the detection of harmonics in appliances. The band pass filter dramatically affects the response time of active filter. The suggested control methodology is capable to eliminate harmonics from distorted input voltage waveform and provides a pure sinusoidal waveform. The prototype of this model is also implemented. Experimental results along with simulation show that the proposed model is quite effective in eliminating HD despite load variations and also useful to compensate the reactive power in electronic home appliances. Hence, this technique is cost effective for domestic users with high quality performance in all aspects. © 2020 IEEE.