In order to study the residual stress of Al2O3 ceramics and kovar alloy after brazing, this article conducted both X-ray diffraction and strain gauges measurement. Using Stress diffractometer and constant strength beam calibration method to examine the x-ray diffraction characteristics of these two materials. And compare measured results and theoretical results. It is shows that the Al2O3 ceramics has two obvious diffraction peaks in 140°~170°, where the diffraction peak at 2θ=153° can reflect the changes of stress more accurately then one at 2θ=146°. For kovar alloy, there is only one diffraction peak at 2θ=149° in range of 140°~170° and it has good linear relationship with stress. © 2016 Trans Tech Publications, Switzerland.