Abstract:

Self-piercing riveted (SPR) connections are gradually being used in cold-formed steel structures due to higher tensile strength, shear strength and connection efficiency compared to those of self- drilling connections. With the purpose of investigating the flexural behavior of truss beams with SPR connections and studying the effects of height and span, as well as diagonal web arrangement, on their flexural stiffness and ultimate bearing capacity, the symmetric vertical static load test was conducted for 5 cold-formed thin-walled truss beam specimens with SPR connections. The finite element software was adopted to simulate the test models, and the more parameters were additionally analyzed. The research indicated that the failure modes of the specimens can be divided into two types: the local strength failure mode occurred when the upper chord flange plate was cracked, the other one occurred when the rivets at joints of truss beams were stripped from the plate. The span-height ratio, spacing of web members, chord thickness and number of rivets had great influence on the flexural stiffness and ultimate bearing capacity of truss beams with SPR connections, while the thickness of web members and the arrangement of diagonal web members had less influence. The truss beam was a simply supported beam with a weak web. A theoretical formula was proposed to calculate the equivalent flexural stiffness of the truss beam with SPR connections based on parametric analysis, and it agreed with the experiment results, so the proposed theoretical formula is valid and can be applied to practical engineering. Keywords: Self-piercing riveted connection Cold-formed steel truss beam Static load test Numerical analysis Flexural behavior (C) 2019 Published by Elsevier Ltd.

Keyword:

Cold-formed steel truss beam Self-piercing riveted connection Static load test Numerical analysis Flexural behavior

Author Community:

  • [ 1 ] [Song, Linlin]Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing, Peoples R China
  • [ 2 ] [Yan, Weiming]Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing, Peoples R China
  • [ 3 ] [Tan, Qinghao]Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing, Peoples R China
  • [ 4 ] [Yu, Cheng]Univ North Texas, Dept Engn Technol, Denton, TX 76203 USA
  • [ 5 ] [Xie, Zhiqiang]Beijing Univ Civil Engn & Architecture, Sch Civil & Transportat Engn, Beijing 100044, Peoples R China

Reprint Author's Address:

  • [Song, Linlin]Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing, Peoples R China

Show more details

Related Keywords:

Source :

JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH

ISSN: 0143-974X

Year: 2019

Volume: 156

Page: 28-45

4 . 1 0 0

JCR@2022

ESI Discipline: ENGINEERING;

ESI HC Threshold:136

JCR Journal Grade:1

Cited Count:

WoS CC Cited Count: 15

SCOPUS Cited Count: 13

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 8

Online/Total:667/10648863
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.