Abstract:

One example of grid reconstruction and blood flow simulation for a patient with internal carotid artery aneurysms was presented. The method accurately duplicates the geometry to provide computer simulations of the blood flow. Initial images were obtained by using CT angiography in DICOM format. The image was processed by using MIMICS software, and the 3D fluid model (blood flow) and 3D solid model (wall) were generated. The subsequent output was exported to the Ansys workbench software to generate the volumetric mesh for further homodynamic study. The fluid model was defined and simulated in CFX software, while the solid model was calculated in ANSYS software. The force data calculated firstly in the CFX software were transferred to ANSYS software, and after receiving the force data, total mesh displacement data were calculated in Ansys software. Then the mesh displacement data were transferred back to CFX software. The data exchange was processed in workbench software. The results of simulation could be visualized in CFX-post. The wall shear stress, wall total pressure and von mises stress were in good agreement with the clinical and pathological practice. The results of this study play an important role in the formation, growth, rupture and prognosis of an aneurysm on clinic application, and maybe a practical tool for planning treatment and follow-up of patients after neurosurgical or endovascular interventions with 3D angiography. © 2010 IEEE.

Keyword:

Bioinformatics Biomedical engineering 3D modeling Angiography Computerized tomography Hemodynamics Mesh generation Computer aided diagnosis Numerical models Shear stress Blood Electronic data interchange Patient treatment

Author Community:

  • [ 1 ] [Xu, Bai-Nan]Department of Neurosurgery, Chinese PLA General Hospital, Beijing 100853, China
  • [ 2 ] [Wang, Fu-Yu]Department of Neurosurgery, Chinese PLA General Hospital, Beijing 100853, China
  • [ 3 ] [Liu, Lei]Department of Neurosurgery, Chinese PLA General Hospital, Beijing 100853, China
  • [ 4 ] [Zhang, Xiao-Jun]College of Mechanical Engineering and Applied, Electronics Technology, Beijing University of Technology, Beijing 100124, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Related Article:

Source :

Year: 2010

Language: English

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count: 1

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 6

Online/Total:693/10549563
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.