Indexed by:
Abstract:
This paper investigates the fire performance of concrete-filled steel tubular (CFST) triple-limb laced columns. Six CFST triple-limb laced columns are tested to measure their fire resistance. The influence of column load ratio and steel type on fire resistance are investigated. For comparison, four CFST single-limb columns in fire are tested. The test results indicate that the three CFST chords in CFST triple-limb laced columns can work together very well in fire because of the binding effect provided by the steel lacing tubes. Finite-element analysis (FEA) models are developed to simulate the CFST triple-limb laced columns in fire. The mechanical behavior, including failure modes, deformation, and load distribution, are discussed. Parametric analysis based on the established FEA model is conducted, and a simplified equation is proposed to predict the fire resistance of CFST triple-limb laced columns.
Keyword:
Reprint Author's Address:
Source :
JOURNAL OF STRUCTURAL ENGINEERING
ISSN: 0733-9445
Year: 2018
Issue: 9
Volume: 144
4 . 1 0 0
JCR@2022
ESI Discipline: ENGINEERING;
ESI HC Threshold:156
Cited Count:
WoS CC Cited Count: 7
SCOPUS Cited Count: 8
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 11
Affiliated Colleges: