• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Liu, Zenghua (Liu, Zenghua.) (Scholars:刘增华) | Zhang, Yongchen (Zhang, Yongchen.) | Xie, Muwen (Xie, Muwen.) | Li, Aili (Li, Aili.) | Bin, Wu (Bin, Wu.) | He, Cunfu (He, Cunfu.) (Scholars:何存富)

Indexed by:

EI Scopus SCIE

Abstract:

Due to the simple wave structure and low-attenuation and non-dispersive properties, the lowest-order shear horizontal mode SHo can realize the efficient large-scale damage detection in plate structures and shows a great application potential in non-destructive testing and structural health monitoring. In order to excite SH(0 )mode in aluminum plates, a direction-tunable shear-horizontal mode array magnetostrictive patch transducer (DT-SHMAMPT) is developed based on the magnetostrictive effect. The proposed DT-SHMA-MPT consists of a transducer sleeve, four identical planar fan-shaped meander coils, four identical fan-shaped NdFeB permanent magnets, and a circular nickel patch. Four identical planar fan-shaped meander coils are connected in parallel to form a meander coil array. These planar fen-shaped meander coils are double-layer structures and made of flexible printed circuit (FPC). The experimental results show that the developed DT-SHMA-MPT can effectively excite and receive a single SHo mode in aluminum plates. For the DT-SHMA-MPT with n planar fan-shaped meander coils and n fanshaped permanent magnets (n = 4, 3,2), its frequency response characteristics are tested at the center frequencies of 775 kHz, 780 kHz, and 783 kHz, which are close to the predicted value. Furthermore, the effects of the number of fan-shaped meander coils and corresponding permanent magnets on the directivity of the transducer are also investigated. The acoustic field distribution or the directivity of the transducer directly depends on the number of fan-shaped meander coils and permanent magnets. Finally, the direction tuning of proposed transducer is investigated. The ability of excitation and reception of this transducer can be controlled by tuning the directional arrangement of fan-shaped meander coils and permanent magnets.

Keyword:

Magnetostrictive patch transducer Shear horizontal mode Array Directional tuning Ultrasonic guided waves

Author Community:

  • [ 1 ] [Liu, Zenghua]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China
  • [ 2 ] [Zhang, Yongchen]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China
  • [ 3 ] [Xie, Muwen]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China
  • [ 4 ] [Li, Aili]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China
  • [ 5 ] [Bin, Wu]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China
  • [ 6 ] [He, Cunfu]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China

Reprint Author's Address:

  • 刘增华

    [Liu, Zenghua]Beijing Univ Technol, Coll Mech Engn & Appl Elect Technol, Beijing 100124, Peoples R China

Show more details

Related Keywords:

Related Article:

Source :

NDT & E INTERNATIONAL

ISSN: 0963-8695

Year: 2018

Volume: 97

Page: 20-31

4 . 2 0 0

JCR@2022

ESI Discipline: MATERIALS SCIENCE;

ESI HC Threshold:260

JCR Journal Grade:1

Cited Count:

WoS CC Cited Count: 38

SCOPUS Cited Count: 43

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 7

Online/Total:717/10626779
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.