• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Ding, H. (Ding, H..) | Shang, K. (Shang, K..) | Lian, L. (Lian, L..) | Zhao, L. (Zhao, L..) | Sheng, L. (Sheng, L..) | Zeng, Y. (Zeng, Y..)

Indexed by:

Scopus

Abstract:

An analog device which can simulate myocardium bridge oppresses mural coronary artery is designed. The device can be used to research the dynamic changes of the proximal and distal hoop stresses. Meanwhile, the independent regulation of the hoop stresses is realized. The “myocardial bridge — coronary artery” analog device is built to adjust the external pressure of the simulated coronary artery and the oppression level of the myocardial bridge and to record the changes of the hoop stresses. The In vitro simulation experiment indicate that the anomaly of hoop stress mainly occurs in the proximal end. As the oppression level increases, the mean proximal hoop stress and the oscillatory value (maximum-minimum) increase obviously. The “myocardial bridge — coronary artery” analog device can provide a method to study the influence of the hoop stress on the mural coronary artery in vitro. © 2015, Silicea-Poligraf All rights reserved.

Keyword:

Hemodynamic; Hoop stress; Mural coronary artery; Myocardial bridge

Author Community:

  • [ 1 ] [Ding, H.]School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
  • [ 2 ] [Ding, H.]Shanghai Medical Instrumentation College, Shanghai, China
  • [ 3 ] [Shang, K.]School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
  • [ 4 ] [Shang, K.]Shanghai Medical Instrumentation College, Shanghai, China
  • [ 5 ] [Lian, L.]School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
  • [ 6 ] [Zhao, L.]School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
  • [ 7 ] [Sheng, L.]School of Medical Instrument and Food Engineering, University of Shanghai for Science and Technology, Shanghai, China
  • [ 8 ] [Sheng, L.]Shanghai Medical Instrumentation College, Shanghai, China
  • [ 9 ] [Zeng, Y.]Biomechanics & Medical Information Institute, Beijing University of Technology, No. 100 PingLeYuan, Beijing, China

Reprint Author's Address:

  • [Zeng, Y.]Biomechanics & Medical Information Institute, Beijing University of Technology, No. 100 PingLeYuan, China

Email:

Show more details

Related Keywords:

Related Article:

Source :

Russian Journal of Cardiology

ISSN: 1560-4071

Year: 2014

Issue: 7

Volume: 111

Page: 51-54

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 11

Online/Total:445/10602054
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185