根据恒压激励应变仪和恒流激励应变仪的温度补偿原理,设计并进行了采用不同应变仪的温度补偿实验,通过分析发现,温度补偿片无法完全消除温度对应变采集的影响;采用补偿片消除温度影响的效果并不优于普通电阻;单位温度变化产生的应变值小于试件的线膨胀系数;短期实验如温度变化不大,可忽略温度对实验的影响.