Indexed by:
Abstract:
The annular baffle has a significant heat enhancement effect in molten salt single thermal storage tank. In order to get the optimum radial dimension of the annular baffle, the effect of radial dimension of the baffle on the heat discharging performance of single thermal storage tank with molten salt is simulated, and the flow field around heat exchanger is analyzed. The results show that the outlet temperature, heat discharging power and heat discharging efficiency reach maximum when the diameter tank of baffle to ratio is 0.6. The results provide a theoretical basis for the design of the molten salt single tank thermal storage tank system. © 2021, Solar Energy Periodical Office Co., Ltd. All right reserved.
Keyword:
Reprint Author's Address:
Email:
Source :
Acta Energiae Solaris Sinica
ISSN: 0254-0096
Year: 2021
Issue: 4
Volume: 42
Page: 312-319
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 9
Affiliated Colleges: