• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Huang, C. (Huang, C..) | Sun, Y. (Sun, Y..) | Wang, H. (Wang, H..) | Pang, M. (Pang, M..) | Wang, W. (Wang, W..) | Wei, W. (Wei, W..)

Indexed by:

EI Scopus SCIE

Abstract:

Air-supported membrane (ASM) envelopes offer an effective solution for creating large interior spaces for buildings with lower energy consumption and carbon emissions. However, there is little research on the thermal performance of ASM envelopes, particularly regarding the natural convection within the air interlayer and its impact on thermal resistance. To address this gap, this study developed a numerical model of ASM envelopes and validated it through experiments. Subsequently, a numerical investigation was conducted to analyze natural convection and thermal resistance while considering factors such as indoor-outdoor temperature difference, membrane emissivity and air interlayer thickness. Results indicated that with the emissivity increased from 0.2 to 1, the thermal resistance of the air interlayer and the envelope decreased by 32.35 % and 9.13 %, respectively. Besides, the thickness of air interlayer also had evident effect on thermal resistance. When it increased from 5 mm to 35 mm, the thermal resistance of the air interlayer and the envelope increased by 156.19 % and 14.74 %, and further results in the heat transfer decreased by 13.85 %. However, the convective heat transfer would remain constant when the thickness exceeded 35 mm. This study provided valuable reference for optimizing the design of ASM envelopes and accurately calculating their thermal resistance. © 2024

Keyword:

Air-supported membrane envelope Numerical simulation Thermal resistance Air interlayer Natural convective

Author Community:

  • [ 1 ] [Huang C.]Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, 100124, China
  • [ 2 ] [Sun Y.]Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, 100124, China
  • [ 3 ] [Wang H.]Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, 100124, China
  • [ 4 ] [Pang M.]Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, 100124, China
  • [ 5 ] [Wang W.]Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, 100124, China
  • [ 6 ] [Wang W.]School of Safety Engineering, Beijing Institute of Petrochemical Technology, Beijing, 102627, China
  • [ 7 ] [Wei W.]Beijing Key Laboratory of Green Built Environment and Energy Efficient Technology, Beijing University of Technology, Beijing, 100124, China

Reprint Author's Address:

Email:

Show more details

Related Keywords:

Source :

Thin-Walled Structures

ISSN: 0263-8231

Year: 2025

Volume: 206

6 . 4 0 0

JCR@2022

Cited Count:

WoS CC Cited Count:

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 10

Affiliated Colleges:

Online/Total:504/10519760
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.