Abstract:

Objective: To propose and numerically simulate a novel stent with triangular wire cross-section so as to compare the hemodynamic effect of endovascular stents in aneurysm with circular, rectangular and triangular cross-section, respectively. Methods: Three aneurysm models were constructed by implanting 3 kinds of stents separately, including one with bare circular wire cross-section stent (named CM), and one with bare rectangular wire cross-section stent (named RM), and one with bare triangular cross-section stent (named TM). An unstented aneurysm model was also constructed to serve as the control (named UM). Four models were preformed with numerical simulation of fluid-structure interaction under the same boundary conditions using finite element method. Results: Compared with TM and CM, RM showed lower velocity, higher flow resistance and longer turn over time, which demonstrated that the effect of blood flow pattern on three stents was decreased in the order of RM, TM, CM. RM could reduce the magnitude and fluctuation of wall shear stress (WSS) more significantly than that of TM and CM. However, the pressure rise of TM and CM was lower than that of RM. WSS distribution and deformation results indicated the possibility of aneurysm development along the distal wall was higher than that along the proximal wall, and the top of aneurysm was in the highest risk of rupture. Conclusions: Three kinds of stents show differences of hemodynamics in aneurysm treatment, which provides significant references for the structural design and optimization of endovascular stent.

Keyword:

Shear flow Flow patterns Structural optimization Structural design Wire Fluid structure interaction Numerical models Numerical methods Hemodynamics Computer simulation Shear stress Stents

Author Community:

  • [ 1 ] [Zeng, Kun]College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China
  • [ 2 ] [Qiao, Ai-Ke]College of Life Science and Bioengineering, Beijing University of Technology, Beijing 100124, China

Reprint Author's Address:

Show more details

Related Keywords:

Source :

Journal of Medical Biomechanics

ISSN: 1004-7220

Year: 2012

Issue: 2

Volume: 27

Page: 220-226

Cited Count:

WoS CC Cited Count: 0

SCOPUS Cited Count:

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 7

Online/Total:605/10564415
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.