The natural ventilation of the light pipe system was simulated by the CFD method. The effects of different factors, including velocity and directions of the outdoor wind, the construction of the terminals, the length of the ventilation pipe, the space between the two coaxial pipe and the diameter of the light pipe on the natural ventilation, was studied. The results shown that the H type terminal has the high natural ventilation effect, and there exists the minimal ventilation volume which vary with the length of the ventilation pipe and the space between the two coaxial pipe, and the ventilation volume increased with the increasing of diameter of light pipe. Those results can provide an theoretic instruction for the application of the light pipe system.