• Complex
  • Title
  • Keyword
  • Abstract
  • Scholars
  • Journal
  • ISSN
  • Conference
搜索

Author:

Huang, Y. (Huang, Y..) (Scholars:黄艳) | Mu, G. C. (Mu, G. C..) | Qin, X. G. (Qin, X. G..) | Lin, J. L. (Lin, J. L..) | Liu, C. (Liu, C..) (Scholars:刘超) | Chen, Z. B. (Chen, Z. B..) | Zeng, Y. J. (Zeng, Y. J..)

Indexed by:

Scopus SCIE

Abstract:

Ultrasonic harmonic scalpel has been widely applied to laparoscopic surgery of gastric cancer, but it has not been evaluated properly in open surgery. The objective of this study was to evaluate the value of the ultrasonic harmonic scalpel in the open radical surgery of gastric cancer. 106 gastric cancer patients who had accepted distal D2 lymphadenectomy were included in this study. Patients were divided into ultrasonic harmonic scalpel (UHS) surgery group (50 cases) and conventional electric scalpel surgery group (56 cases). UHS surgery group patients were accepted surgery by ultrasonic harmonic scalpel. Instead, conventional electric scalpel surgery group patients were accepted surgery by monopolar electrocautery shovel and other traditional instruments. Then the average operation time, intra-operative blood loss, number of harvested lymph nodes, average post operative drainage within 3 days, and postoperative hospital stay were collected and compared between the two groups. The average operation time, blood loss, postoperative hospital stay in UHS group were significantly lower than traditional group (P < 0.05). The number of lymph node dissection was significantly higher than conventional surgery group (P < 0.05). There were no difference between two groups in average drainage within 3 days after surgery and the hospitalization costs (P > 0.05). In the presence of atherosclerotic patients, the average operation time, blood loss in UHS surgery group were significantly lower than the traditional group (P < 0.05). Ultrasonic harmonic scalpel may have better effect in the radical surgery of gastric cancer patients. It meets the requirements of the future development of precise surgical procedure.

Keyword:

D2 lymphadenectomy Ultrasonic harmonic scalpel Gastric cancer Surgery

Author Community:

  • [ 1 ] [Huang, Y.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China
  • [ 2 ] [Mu, G. C.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China
  • [ 3 ] [Qin, X. G.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China
  • [ 4 ] [Lin, J. L.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China
  • [ 5 ] [Liu, C.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China
  • [ 6 ] [Chen, Z. B.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China
  • [ 7 ] [Zeng, Y. J.]Beijing Univ Technol, Ctr Biomed Engn, Beijing 100022, Peoples R China

Reprint Author's Address:

  • 黄艳

    [Huang, Y.]Guangxi Med Univ, Affiliated Hosp 1, Dept Gastrointestinal Surg, Nanning 530021, Peoples R China

Show more details

Related Keywords:

Source :

CLINICAL & TRANSLATIONAL ONCOLOGY

ISSN: 1699-048X

Year: 2013

Issue: 11

Volume: 15

Page: 932-937

3 . 4 0 0

JCR@2022

ESI Discipline: CLINICAL MEDICINE;

JCR Journal Grade:4

CAS Journal Grade:4

Cited Count:

WoS CC Cited Count: 9

SCOPUS Cited Count: 8

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 5

Online/Total:660/10645141
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.