Indexed by:
Abstract:
介绍了有源功率因数校正电路的三种boost拓扑方案——硬开关、无源软开关和有源软开关,并采用三种拓扑分别研制了4 kW功率因数校正装置,对三种拓扑方案做了效率、谐波畸变率、功率因数、EMI测试,对比分析测试结果,总结了各自的优缺点,对三种拓扑的适用场合给出了建议.将研究的有源功率因数校正装置应用于单相逆变焊接电源,并在实际焊接情况下对电源进行了输入性能测试,结果表明所测装置性能良好,整个焊接过程中输入电流连续变化,呈正弦波状,能够跟随负载的波动实时响应,完全达到了功率因素校正的目的.
Keyword:
Reprint Author's Address:
Email:
Source :
电焊机
ISSN: 1001-2303
Year: 2012
Issue: 3
Volume: 42
Page: 18-22
Cited Count:
WoS CC Cited Count: 0
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count: 3
Chinese Cited Count:
30 Days PV: 6
Affiliated Colleges: