Indexed by:
Abstract:
The fatigue performance and microstructure of polycrystalline copper treated by one (UUV1), two (UUV2), three (UUV3) passes of unconstraint ultrasonic vibration (UUV) treatment were investigated in this paper. The surface roughness, fatigue life, microstructure, and plastic strain energy before and after UUV treatment were compared. The results revealed that the surface integrity of the sample for UUV treatment higher than that of the original sample, and the microscope observation found that the grain orientation, the dislocation density, the low angle grain boundaries, the plastic strain energy of the damaged sample restored to the original state to a great extent after UUV treatment. The fatigue crack initiation life increased by 3 times after UUV3 treatment. © 2024