Indexed by:
Abstract:
The development of electrohydrodynamic (EHD) micropump was introduced. The fabrication process of EHD micropump was presented from the material selection, optimal design of microelectrode and assembly process. PDMS was used making micro fluid channel through the casting molding process. Anodic bonding was used in micropump assembly packing. Flow experiment was carried out on ethyl alcohol. The results indicate that the EHD micropump can achieve a maximum flow rate is 92 uL/min at applied voltage of 90 V.
Keyword:
Reprint Author's Address:
Email:
Source :
Journal of Engineering Thermophysics
ISSN: 0253-231X
Year: 2011
Issue: 7
Volume: 32
Page: 1215-1217
ESI Discipline: PHYSICS;
JCR Journal Grade:4
CAS Journal Grade:4
Cited Count:
SCOPUS Cited Count:
ESI Highly Cited Papers on the List: 0 Unfold All
WanFang Cited Count:
Chinese Cited Count:
30 Days PV: 10
Affiliated Colleges: