We studied the relationship between the RF power, the chamber pressure and the film stress for deposited the silicon nitride film by Plasma Enhance Chemical Vapor Deposition (PECVD). It shows that even if using the RF power(13. 56 MHz) as the excitation of plasma, the compressive silicon nitride film can be obtained easily. The low stress film shows the good uniformity through the mapping measurement by variable angle spectroscopic elhpsometry (VASE). The silicon nitride films chemical composition was analyzed by FTIR (Fourier Trans-form Infrared Spectroscopy).