The bolted-flange connection is a new application for mounting rectangular hollow section (RHS) columns in prefabricated multi-high-rise steel structures, which may bear the combination of bending moment and shear under permanent, live, wind loads or earthquake. The performance of the bolted-flange connection used in the structural column is different from that in its popular usage in the pipe because the subjected force is different. To investigate the bearing performance of a bolted-flange connection under the combination of bending moment and shear, this study conducted static tests and finite element analysis (FEA) of 12 column-to-column bolted-flange connections with different flange thicknesses, bolt edge distances, flange edge widths and bolt hole diameters, as well as one column without a connection. The test agreed well with the FEA, which verifies the FEA. The influences of the flange thickness, bolt edge distance, flange edge width and bolt hole diameter on the stiffness and strength of the connections, bolt tension and contact force were studied, and the failure mode and mechanism of the connection were obtained. A significant prying action occurred on the flange contact surface, increased the bolt tension in the tensile region, and caused the bolt shanks to experience tension and bending moment. The flange thickness had a large impact on the prying force, while other factors had less of an effect. Based on the yield line theory, the bearing mechanism of the connection was obtained. The formulas for the yield bearing capacity were proposed and were verified by the test and FEA. (C) 2018 Elsevier Ltd. All rights reserved.

Keyword:

Yield bearing capacity Bending-shear bearing performance Column-to-column connection Simplified calculation formulas Bolted-flange connection Connection stiffness

Author Community:

  • [ 1 ] [Liu, X. C.]Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China
  • [ 2 ] [He, X. N.]Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China
  • [ 3 ] [Wang, H. X.]Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China
  • [ 4 ] [Yang, Z. W.]Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China
  • [ 5 ] [Pu, S. H.]Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China
  • [ 6 ] [Zhang Ailin]Beijing Univ Technol, Beijing Engn Res Ctr High Rise & Large Span Prest, Beijing 100024, Peoples R China
  • [ 7 ] [Liu, X. C.]Beijing Univ Technol, Beijing Key Lab Earthquake Engn & Struct Retrofit, Beijing 100124, Peoples R China
  • [ 8 ] [Liu, X. C.]Beijing Univ Civil Engn & Architecture, Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China
  • [ 9 ] [Zhang Ailin]Beijing Univ Civil Engn & Architecture, Beijing Adv Innovat Ctr Future Urban Design, Beijing 100044, Peoples R China

Reprint Author's Address:

  • 刘学春

    [Liu, X. C.]Beijing Univ Technol, Beijing 100124, Peoples R China

Show more details

Related Keywords:

Source :

JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH

ISSN: 0143-974X

Year: 2018

Volume: 145

Page: 28-48

4 . 1 0 0

JCR@2022

ESI Discipline: ENGINEERING;

ESI HC Threshold:156

Cited Count:

WoS CC Cited Count: 60

SCOPUS Cited Count: 73

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 9

Online/Total:663/10626291
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.