Background: BJUT-II VAD is a novel left ventricular assist device (LVADs), directly implanted into the ascending aorta. The pulsatile support mode is proposed to achieve better unloading performance than constant speed mode. However, the hemodynamic effects of this support mode on the aorta are still unclear. The aim of this study was to clarify the hemodynamic effects BJUT-II VAD under pulsatile support mode on the aorta. Material/Methods: Computational fluid dynamics (CFD) studies, based on a patient-specific aortic geometric model, were conducted. Wall shear stress (WSS), averaged WSS (avWSS), oscillatory shear index (OSI), and averaged helicity density (Ha) were calculated to compare the differences in hemodynamic effects between pulsatile support mode and constant speed mode. Results: The results show that avWSS under pulsatile support mode is significantly higher than that under constant speed mode (0.955Pa vs. 0.675Pa). Similarly, the OSI value under pulsatile mode is higher than that under constant speed mode (0.104 vs. 0.057). In addition, Ha under pulsatile mode for all selected cross-sections is larger than that under constant mode. Conclusions: BJUT-II VAD, under pulsatile control mode, may prevent atherosclerosis lesions and aortic remodeling. The precise effects of pulsatile support mode on atherosclerosis and aortic remodeling need to be further studied in animal experiments.

Keyword:

Cardiovascular System Hemodynamics Heart-Assist Devices

Author Community:

  • [ 1 ] [Gu, Kaiyun]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing, Peoples R China
  • [ 2 ] [Gao, Bin]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing, Peoples R China
  • [ 3 ] [Chang, Yu]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing, Peoples R China
  • [ 4 ] [Zeng, Yi]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing, Peoples R China

Reprint Author's Address:

  • 常宇

    [Chang, Yu]Beijing Univ Technol, Sch Life Sci & BioEngn, Beijing, Peoples R China

Show more details

Related Keywords:

Source :

MEDICAL SCIENCE MONITOR

ISSN: 1643-3750

Year: 2016

Volume: 22

Page: 2284-2294

3 . 1 0 0

JCR@2022

ESI Discipline: CLINICAL MEDICINE;

ESI HC Threshold:203

CAS Journal Grade:4

Cited Count:

WoS CC Cited Count: 5

SCOPUS Cited Count: 5

ESI Highly Cited Papers on the List: 0 Unfold All

WanFang Cited Count:

Chinese Cited Count:

30 Days PV: 12

Online/Total:803/10663674
Address:BJUT Library(100 Pingleyuan,Chaoyang District,Beijing 100124, China Post Code:100124) Contact Us:010-67392185
Copyright:BJUT Library Technical Support:Beijing Aegean Software Co., Ltd.